ITRON SL7000 energy meter's error decoding table

data function detecting the alarm errors (9digits: 9 half bytes)
On the first line: None fatal alarms
First digit
Phase intensity imbalance[1-2] Diagnosis and fraud Half byte 0: Bit 0 1,3,5,7 1
Phase intensity imbalance[2-3] Diagnosis and fraud Half byte 0: Bit 1 2,3,6,7
Phase intensity imbalance[1-3] Diagnosis and fraud Half byte 0: Bit 2 4,5,6,7
Not used
Second digit
Voltage disconnection (phase 1) voltage Diagnosis and fraud Half byte 1: Bit 0 1,3,5,7,9,B,D,F 2
Voltage disconnection (phase 2) Diagnosis and fraud Half byte 1: Bit 1 2,3,6,7,A,B,E,F
Voltage disconnection (phase 3) Diagnosis and fraud Half byte 1: Bit 2 4,5,6,7,C,D,E,F
Opening the lid Diagnosis and fraud Half byte 1: Bit 3 8,9,A,B,C,D,E,F
Third digit
External alarm Logic input Half byte 2: Bit 0 1,3,5,7 3
Configuration inconsistency Any function Half byte 2: Bit 1 2,3,6,7
Non-volatile mermory Memory administrator Half byte 2: Bit 2 4,5,6,7
Not used
Fourth digit
Absence of internal consumption Diagnosis and fraud Half byte 3: Bit 0 1,3,5,7,9,B,D,F 4
Absence of external consumption Diagnosis and fraud Half byte 3: Bit 1 2,3,6,7,A,B,E,F
Residual voltage Diagnosis and fraud Half byte 3: Bit 2 4,5,6,7,C,D,E,F
Neutral intensity Diagnosis and fraud Half byte 3: Bit 3 8,9,A,B,C,D,E,F
Fifth digit
Loss of voltage (phase 3) Qualimetry Half byte 4: Bit 0 1,3,5,7,9,B,D,F 5
Voltage dip (phase 3) Qualimetry Half byte 4: Bit 1 2,3,6,7,A,B,E,F
Overvoltage (phase 3) Qualimetry Half byte 4: Bit 2 4,5,6,7,C,D,E,F
Current reversal (phase 3) Diagnosis and fraud Half byte 4: Bit 3 8,9,A,B,C,D,E,F
Sixth digit
Loss of voltage (phase 2) Qualimetry Half byte 5: Bit 0 1,3,5,7,9,B,D,F 6
Voltage dip (phase 2) Qualimetry Half byte 5: Bit 1 2,3,6,7,A,B,E,F
Overvoltage (phase 2) Qualimetry Half byte 5: Bit 2 4,5,6,7,C,D,E,F
Current reversal (phase 2) Diagnosis and fraud Half byte 5: Bit 3 8,9,A,B,C,D,E,F
Seventh digit
Loss of voltage (phase 1) Qualimetry Half byte 6: Bit 0 1,3,5,7,9,B,D,F 7
Voltage dip (phase 1) Qualimetry Half byte 6: Bit 1 2,3,6,7,A,B,E,F
Overvoltage (phase 1) Qualimetry Half byte 6: Bit 2 4,5,6,7,C,D,E,F
Current reversal (phase 1) Diagnosis and fraud Half byte 6: Bit 3 8,9,A,B,C,D,E,F
Eighth digit
Communication error Communications Half byte 7: Bit 0 1,3,5,7,9,B,D,F 8
Programming inconsistency Communications Half byte 7: Bit 1 2,3,6,7,A,B,E,F
Loss of time Event administrator Half byte 7: Bit 2 4,5,6,7,C,D,E,F
External clock inconsistency Internal clock Half byte 7: Bit 3 8,9,A,B,C,D,E,F
Nineth digit
Triggering of the watchdog Diagnosis and fraud Half byte 8: Bit 0 1,3,5,7,9,B,D,F 9
Battery alarm Diagnosis and fraud Half byte 8: Bit 1 2,3,6,7,A,B,E,F
Loss of neutral Diagnosis and fraud Half byte 8: Bit 2 4,5,6,7,C,D,E,F
Tempareture Diagnosis and fraud Half byte 8: Bit 3 8,9,A,B,C,D,E,F
On the second line: Fatal errors
RAM error Diagnosis and fraud Half byte 0: Bit 0 1,3,5,7,9,B,D,F
Program memory error Diagnosis and fraud Half byte 0: Bit 1 2,3,6,7,A,B,E,F
Checksum error in a memory area Diagnosis and fraud Half byte 0: Bit 2 4,5,6,7,C,D,E,F
Numerious inconsistencies of the external clock Internal clock Half byte 0: Bit 3 8,9,A,B,C,D,E,F